Change language

Analog I/O module

Ezi-IO-CT-AD08-T

Price on request

Product inquiry

Contact details

Product details

Item no. – Product name Ezi-IO-CT-AD08-T

Drawings or files? Simply reply to our response email with the attachment.

Produktbeschreibung

Analog input module for CC-Link IE TSN: acquires the measured values of pressure, temperature, level or distance sensors directly at the machine and makes them available to the controller over the network – without long, noise-prone analog lines to the control cabinet.

Design and function
Eight channels in one module measure either voltage (up to ±10 V) or current (0–20 mA). Input mode and range are set per channel, so different sensors can work on a single module. A moving average filter smooths noisy signals before they reach the controller. All eight channels are converted within 200 µs – so even fast signal changes are captured. Wiring is via a terminal block, mounting on a DIN rail.

CC-Link IE TSN communication
The module is integrated into CC-Link IE TSN networks as a class B station and operates asynchronously or cycle-synchronously, depending on the application. Two RJ45 ports allow daisy-chaining from module to module, with up to 100 m between stations.

Technische Spezifikationen

I/O module Ezi-IO-CT-AD08-T

Supply voltage
24 V DC ±10 %
Current consumption
120 mA
Connection method
Terminal block
Protocol
CC-Link IE TSN, Remote Device Station, Authentication Class B
Bus interface
2 × RJ45
Cable
STP (shielded twisted pair), Cat. 5e or higher, max. 100 m
LED display
Power status (PWR), CC-Link IE TSN status (RUN), Operation error (ERR), CC-Link IE TSN connection (P1, P2)
Ambient temperature (in use)
0 … 50 °C
Ambient temperature (storage)
-20 … 70 °C
Humidity in use (non-condensing)
35 … 85 %
Humidity in storage (non-condensing)
10 … 90 %
Vibration resistance
0.5 g

Analog input (voltage) Ezi-IO-CT-AD08 – Voltage Input

Number of channels
8
Max. signal input
±15 V
Signal range
−10 … 10 V, −5 … 5 V, −2.5 … 2.5 V, 0 … 10 V
Range setting method
Parameter setting window (per channel CH1–CH8), DIP switch (in pairs CH1/CH2, CH3/CH4, CH5/CH6, CH7/CH8)
Impedance
1 MΩ
Max. resolution
1/8,191 (full scale)
Accuracy at 25 °C
±0.3 % (full scale)
Accuracy at 0–50 °C
±0.4 % (full scale)
Conversion cycle
200 µs (for 8 channels)
A/D converted data
−10 … 10 V: −4,096 … 4,095, −5 … 5 V: −4,096 … 4,095, −2.5 … 2.5 V: −4,096 … 4,095, 0 … 10 V: 0 … 8,191
Isolation
Digital isolation between analog input and CC-Link IE TSN connectors (channels not isolated from each other)

Analog input (current) Ezi-IO-CT-AD08 – Current Input

Number of channels
8
Max. signal input
±30 mA
Signal range
0 … 20 mA
Range setting method
Parameter setting window (per channel CH1–CH8), DIP switch (in pairs CH1/CH2, CH3/CH4, CH5/CH6, CH7/CH8)
Impedance
249 Ω
Max. resolution
1/8,191 (full scale)
Accuracy at 25 °C
±0.3 % (full scale)
Accuracy at 0–50 °C
±0.6 % (full scale)
Conversion cycle
200 µs (for 8 channels)
A/D converted data
0 … 20 mA: 0 … 8,191
Isolation
Digital isolation between analog input and CC-Link IE TSN connectors (channels not isolated from each other)