Change language

Analog I/O module

Ezi-IO-EC-AD08-T

Base price €360,00

Required accessories for commissioning

If compatible accessories are already available, you can deselect these items.

Total €360,00
excl. VAT Delivery time: 2–4 weeks
Quantity

Product inquiry

Contact details

Product details

Item no. 53306010000 Product name Ezi-IO-EC-AD08-T

Drawings or files? Simply reply to our response email with the attachment.

Produktbeschreibung

Analog input module for EtherCAT: acquires the measured values of pressure, temperature, level or distance sensors directly at the machine and makes them available to the controller over the network – without long, noise-prone analog lines to the control cabinet.

Design and function
Eight channels in one module measure either voltage (up to ±10 V) or current (0–20 mA). Input mode and range are set per channel, so different sensors can work on a single module. A moving average filter smooths noisy signals before they reach the controller. All eight channels are converted within 200 µs – so even fast signal changes are captured. Wiring is via a terminal block, mounting on a DIN rail.

EtherCAT communication
The module is integrated using the standard CiA 401 profile and therefore works with common EtherCAT masters. Free Run, SM Event and DC Sync are available for cycle-synchronous operation; firmware updates run over the network (FoE) without removing the module.

Technische Spezifikationen

I/O module Ezi-IO-EC-AD08-T

Supply voltage
24 V DC ±10 %
Current consumption
120 mA
Connection method
Terminal block
Protocol
CoE (CiA 401 I/O Profile), FoE (firmware download)
Synchronization
Free Run, SM Event, DC SYNC Event
Bus interface
2 × RJ45 connector
Cable
STP (shielded twisted pair), Cat. 5e or higher, max. 100 m
LED display
Power status (PWR), EtherCAT status (RUN), Operation error (ERR), EtherCAT connection (LA IN, LA OUT)
Ambient temperature (in use)
0 … 50 °C
Ambient temperature (storage)
-20 … 70 °C
Humidity in use (non-condensing)
35 … 85 %
Humidity in storage (non-condensing)
10 … 90 %
Vibration resistance
0.5 g

Analog input (voltage) Ezi-IO-EC-AD08 – Voltage Input

Number of channels
8
Max. signal input
±15 V
Signal range
−10 … 10 V, −5 … 5 V, −2.5 … 2.5 V, 0 … 10 V
Range setting method
SDO communication (per channel CH1–CH8), DIP switch (in pairs CH1/CH2, CH3/CH4, CH5/CH6, CH7/CH8)
Impedance
1 MΩ
Max. resolution
1/8,191 (full scale)
Accuracy at 25 °C
±0.3 % (full scale)
Accuracy at 0–50 °C
±0.4 % (full scale)
Conversion cycle
200 µs (for 8 channels)
A/D converted data
−10 … 10 V: −4,096 … 4,095, −5 … 5 V: −4,096 … 4,095, −2.5 … 2.5 V: −4,096 … 4,095, 0 … 10 V: 0 … 8,191
Isolation
Digital isolation between analog input and communication (channels not isolated from each other)

Analog input (current) Ezi-IO-EC-AD08 – Current Input

Number of channels
8
Max. signal input
±30 mA
Signal range
0 … 20 mA
Range setting method
SDO communication (per channel CH1–CH8), DIP switch (in pairs CH1/CH2, CH3/CH4, CH5/CH6, CH7/CH8)
Impedance
249 Ω
Max. resolution
1/8,191 (full scale)
Accuracy at 25 °C
±0.3 % (full scale)
Accuracy at 0–50 °C
±0.6 % (full scale)
Conversion cycle
200 µs (for 8 channels)
A/D converted data
0 … 20 mA: 0 … 8,191
Isolation
Digital isolation between analog input and communication (channels not isolated from each other)