Analog I/O module
Analog input module for EtherCAT: acquires the measured values of pressure, temperature, level or distance sensors directly at the machine and makes them available to the controller over the network – without long, noise-prone analog lines to the control cabinet.
Design and function
Eight channels in one module measure either voltage (up to ±10 V) or current (0–20 mA). Input mode and range are set per channel, so different sensors can work on a single module. A moving average filter smooths noisy signals before they reach the controller. All eight channels are converted within 200 µs – so even fast signal changes are captured. Wiring is via a terminal block, mounting on a DIN rail.
EtherCAT communication
The module is integrated using the standard CiA 401 profile and therefore works with common EtherCAT masters. Free Run, SM Event and DC Sync are available for cycle-synchronous operation; firmware updates run over the network (FoE) without removing the module.
I/O module Ezi-IO-EC-AD08-T
Analog input (voltage) Ezi-IO-EC-AD08 – Voltage Input
Analog input (current) Ezi-IO-EC-AD08 – Current Input
Fieldbus File
ZIP ESI - Ezi-IO EtherCAT0,1 MB