Digital I/O module
Remote digital I/O module for EtherCAT: brings sensors, switches and actuators onto the network right where they sit on the machine – instead of running every single wire back to the control cabinet. That saves cable, terminals and time during installation and troubleshooting.
Design and function
Proximity switches, light barriers and limit switches connect to the inputs; valves, relays and indicator lights to the outputs. Input-only, output-only and combined modules are available with 16 or 32 channels, each in NPN or PNP versions – to match the sensors you already use. Wiring is via e-CON connectors or a terminal block, mounting on a DIN rail. LEDs show the state of every channel directly on the module; the 32-channel modules are photocoupler-isolated from the field side.
EtherCAT communication
The modules are integrated using the standard CiA 401 profile and therefore work with common EtherCAT masters; synchronization is via Free Run or SM Event. Option A modules additionally support DC Sync for cycle-synchronous operation, firmware updates over the network (FoE) and an adjustable input filter against contact bounce and noise pulses.
I/O module Ezi-IO-EC-O16N-E
Digital output Ezi-IO EC transistor output 16 CH NPN
Fieldbus File
ZIP ESI - Ezi-IO EtherCAT0,1 MB