Digital I/O module
Remote digital I/O module for RS-485: brings sensors, switches and actuators onto the network right where they sit on the machine – instead of running every single wire back to the control cabinet. That saves cable, terminals and time during installation and troubleshooting.
Design and function
Proximity switches, light barriers and limit switches connect to the inputs; valves, relays and indicator lights to the outputs. Available are input modules with 16 channels (NPN or PNP), an output module with 16 channels (NPN) and combined modules with 8 inputs and 8 outputs each – to match the sensors you already use.
RS-485 communication
Up to 16 modules share a single RS-485 line in a daisy chain – an economical solution where no fieldbus is available. The baud rate is adjustable up to 921,600 bps. A Windows user program is available for commissioning and testing, and a Motion Library (API) for integration into your own applications.
I/O module Ezi-IO-RS-I8NO8
Digital input Ezi-IO RS DC input 8 CH NPN
Digital output Ezi-IO RS transistor output 8 CH NPN